Vista de pagina 99
94
CHAPTER 5
The Measurements
Group View - allows the user to view the Room trace and the Processor trace in the lower
window, giving the ability to visually set the EQ filters to the “raw” room response and
view the resultant corrected frequency response in the upper Results graph.
Figure 5.9. Frequency Response measurement (coherence and frequency response on top, phase on bottom)
5.4.2. Description of the Measurement
The horizontal axis of the Frequency Response graph is a logarithmic display with a resolu-
tion of 48 points/octave typical. The graph can be displayed as full bandwidth or in five fre-
quency spans. The following characteristics of the audio signal measurement are displayed:
Amplitude — amplitude in dB, vs. frequency
Phase — phase in degrees, vs. frequency
Coherence — coherence in percent, vs. frequency
dB S/N — signal-to-noise ratio in dB, vs. frequency (an alternative measurement scale to
Coherence)