89
CHAPTER 5
The Measurements
5.2.6. All
To view the console, processor and microphone traces simultaneously in three separate
graphs, click the All button or select View > All.
Figure 5.4. Line Spectrum measurement, All view
5.3. DELAY FINDER
5.3.1. Overview
Delay Finder computes and displays the amplitude response of the measured system in the
time domain. SIM 3 uses FFTs to calculate an impulse response, resembling the response
that would be seen if an ideal pulse was applied to the system input and the output was
viewed on an oscilloscope.